Skip to content

4.6 Bouwfysische eigenschappen — NLRS_C_ZTA_max <=1

Controleert of de parameter NLRS_C_ZTA_max is ingevuld voor family types met een Assembly Code in de 31.*-reeks waarvoor eisen gelden aan maximale contactgeluidisolatie conform de BIM Basis ILS.


{
  "Id": "0c576bca-17d3-45ee-b3c0-d88754c96226",
  "Filter": {
    "Type": "filterCollection",
    "Properties": [
      {
        "Name": "Operator",
        "Value": "and",
        "Type": null
      }
    ],
    "SubFilters": [
      {
        "Type": "familySymbolFilter",
        "Properties": [],
        "SubFilters": []
      },
      {
        "Type": "queryFilter",
        "Properties": [
          {
            "Name": "Query",
            "Value": "$[$string(values.assemblyCode) ~> /^31\\.(1[012]|2[012345]|3[01234]|4[01])$/i]",
            "Type": null
          }
        ],
        "SubFilters": []
      }
    ]
  },
  "Validation": {
    "Type": "validation",
    "Name": "NLRS_C_ZTA_max <=1",
    "ErrorMessage": "#### Issue\n\nDe parameter **NLRS_C_ZTA_max** is niet ingevuld voor dit element.\n\nDeze parameter is vereist voor bouwdelen waarvoor eisen gelden aan **maximale contactgeluidisolatie** .\n\n#### Oplossing\n\nVul een geldige waarde in voor de parameter **NLRS_C_ZTA_max** :\n\n- Controleer of het element een **scheidende constructie** betreft\n- Vul de waarde in als **typeparameter** , conform de geldende project- of contractspecificaties\n\n#### Informatie\n\nVolgens de **BIM Basis ILS – §4.6 Bouwfysische eigenschappen**  moeten scheidende bouwdelen met relevante **Assembly Codes (31.\\*)**  voorzien zijn van een waarde voor **ZTA_max** .\n\nZTA_max beschrijft de **maximaal toegestane contactgeluidsoverdracht**  tussen aangrenzende ruimten en is noodzakelijk voor akoestische toetsing en gegevensuitwisseling.\n",
    "Properties": [
      {
        "Name": "valueToValidate",
        "Value": {
          "Type": "sharedParameterSelector",
          "Properties": [
            {
              "Name": "guid",
              "Value": "b97dbaac-47a2-4205-872e-46a86cfefd3c",
              "Type": "string"
            }
          ]
        }
      },
      {
        "Name": "Validator",
        "Value": {
          "Type": "value",
          "Properties": [
            {
              "Name": "value",
              "Value": "string:ShouldNotBeEmpty",
              "Type": "string"
            }
          ]
        }
      },
      {
        "Name": "expectedValue",
        "Value": {
          "Type": "staticValueSelector",
          "Properties": [
            {
              "Name": "value",
              "Value": "not empty",
              "Type": "string"
            }
          ]
        }
      }
    ],
    "SubValidations": []
  },
  "Details": {
    "Name": "NLRS_C_ZTA_max <=1",
    "Impact": 4,
    "Priority": 3,
    "Tags": [
      "4.6 Bouwfysische eigenschappen"
    ],
    "Description": "Controleert of de parameter NLRS_C_ZTA_max is ingevuld voor family types met een Assembly Code in de 31.*-reeks waarvoor eisen gelden aan maximale contactgeluidisolatie conform de BIM Basis ILS.\n",
    "HelpUrl": "https://help.daqs.io/NL/NLRS/NLRS_C_ZTA_max/?nav=false",
    "TimeToSolve": 5,
    "AllDisciplines": true,
    "Disciplines": []
  },
  "Metadata": [
    {
      "Label": "AssemblyCode",
      "Selector": {
        "Type": "querySelector",
        "Properties": [
          {
            "Name": "query",
            "Value": "values.assemblyCode",
            "Type": null
          }
        ]
      }
    }
  ]
}